Sharp Displays - RS232 & Ethernet Control Codes

Опубликовано: 05 Май 2026
на канале: Arctic's 8-Bit Bytes
151
5

Epson Projectors - RS232 & Ethernet #coding #programming #lua #python #telnet

Please subscribe and check out some of the other AV programming & engineering videos on my channel! Arctics 8-bit bytes! #arctics8bit

In this video I'm showing the RS232 & Ethernet communication settings for the latest Sharp Displays. There is a code that you can send to the Sharp display to enable POWER ON when off. I believe this makes sure the ethernet port stays LIVE during a power off. This command should only be sent 1 time to the display. Unfortunately, I don't have good 'responses' information to post about the sharps from the Query commands.

If you are testing the display without a programming interface, Hercules is an excellent tool to test device communications!


RS232 - 8, 1, N 9600 or 38400 (old)
ethernet port - 10008


Some Sharp displays require
2 spaces between command & \x0D

If the command 'POWR1 \x0d ' doesn't work
try 'POWR 1\x0d' instead!

Issue this command one time
RSPW2 \x0D
This sets the display to IP/Serial
mode to enable - allows power on
when display is off


power on- "POWR1 \x0D"
power off - "POWR0 \x0D"

input hdmi1 - "IAVD1 \x0D"
input hdmi2 - "IAVD2 \x0D"
input hdmi3 - "IAVD3 \x0D"

AV mute - "AVM1 \x0d"
AV unmute - "AVM0 \x0d"
audio mute - "MUTE1 \x0d"
audio unmute - "MUTE0 \x0d"
volume 0%- "VOLM000 \x0d"
volume 100%- "VOLM100 \x0d"

query commands
power - "POWR? \x0d"
input - "INPS? \x0d"
AV mute - "BMOD? \x0d"