Manual failover triggered from CLI of active cluster node (control-plane). Failure Scenario 2 - Manual cluster failover
1. No Special Config
Result - ~53s w/ 42 pings lost
2. GRE Keepalives enabled ***
Result - ~36s w/ 22 pings lost
3. GRE KA’s and graceful-restart enabled
Result - ~28s w/ 14 pings lost
4. GRE KA’s and BFD enabled
Result - ~1m10s w/ ~66 pings lost