How to reset Error Canon iR 2016/ 2018/2020/2022 solution code: E000-0000, E001-0000, E002, E003.

Опубликовано: 28 Сентябрь 2024
на канале: Tech Humayun kabir
15,429
122

How to reset Error Canon iR 2016/ 2018/2020/2022/2025/2030 / 2318/ 2320/iR 2420/ 2422/1600/2000/
2010/1600/2000/2010 solution code: E000-0000, E001-0000, E001-0001, E002-0000, E003-0000, E003-0001.


Code: E000-0000

Fixing temperature abnormal rise. The temperature detected by the main or sub thermistor does not rise to the specified value during startup control.

Remedy: Check the fixing film connector. - Replace the
fixing film unit. Replace the DC controller PCB.
★ ★ ★ ★ ★ ★ ★ ★ ★


Code E001-0000

Fixing unit temperature rise detection (by main thermistor). The main thermistor detected an abnormally high temperature (240 deg C) during temperature control.

Remedy: Check the connector of the fixing film unit. Replace the fixing film unit. Replace the DC controller PCB.
★ ★ ★ ★ ★ ★ ★ ★ ★


Code: E001-0001

Fixing unit temperature rise detection (by sub thermistor). The sub thermistor detected an abnormally high temperature (295 deg C) during temperature control.

Remedy: Check the connector of the fixing film unit. Replace the fixing film unit. Replace the DC controller PCB.
★ ★ ★ ★ ★ ★ ★ ★ ★


Code: E002-0000

Low temperature during temperature control. The target temperature is not reached during temperature control.

Remedy: Check the connector of the fixing film unit. Replace the fixing film unit. Replace the DC controller PCB.
★ ★ ★ ★ ★ ★ ★ ★ ★


Code: E003-0000

Abnormally low temperature (detected by main
thermistor) After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation.

Remedy:Check the connector of the fixing film unit. Replace the fixing film unit. Replace the DC controller PCB.
★ ★ ★ ★ ★ ★ ★ ★ ★


Code: E003-0001

Abnormally low temperature (detected by sub thermistor) After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.

Remedy: Check the connector of the fixing film unit. Replace the fixing film unit. Replace the DC controller PCB.
★ ★ ★ ★ ★ ★ ★ ★ ★