Ricoh mp 2014
Code sc 542-03
Reload failure: Heater damage Normal (no pre-rotation): • The reload temperature is not reached for 35 seconds after heater control starts. Pre- rotation: The reload temperature is not reached for 90 seconds after heater control starts.
Heater damaged. After over-heat prevention
Replace the heater. Clear this SC by executing SP5-810-001.