Flap Barrier with ESD tester and Access Control System
Make : NABARCOM .
Our Flap Barriers is a motorized electromechanical drive system. In this model sensing is achieved by an array of optical beam sensors. It
provide user friendly, rapid access control to restricted areas at metro railways, office complexes,
factories, banks, amusement parks and stadiums, Call centers, BPO’s, and IT Parks, These barriers can
be integrated either with card access systems or ticketing systems to ensure quick and automatic
clearance while keeping accurate/Entry and entrance record.
Features:
Motorized electro mechanical drive system
Opening time less than 0.8 Seconds
Passage width 550 (+50)mm.
Detection of tail gating (Optional)
Micro Process Controller based control Unit
Sensing is achieved by an array of optical beam sensors
Cabinet is available in Mild Steel powder coated or Stainless Steel with LED Acrylic Flap
Available with Line Indicator for go Green Arrow & for Stop Red Cross
Handicapped or two wheeler movement (optional)
Lane Indicator for Entry/Noentry.
LCD alfa numercal display for In/Out Count.(inbuilt)
C E approved.
Integration any readers/panels available in the market
Technical Features:
1.Over all dimensions: L650xH1020xW300 mm
2. Sheet Thickness MS/SS 304: SWG 16
3. Flap Thickness: 19.5mm
4. Protection I.P: 44
5. Voltage VAC : 230
6. Current mA (max): 450
7. Power consumption: Watts 100max
8. Frequency Hz: 50
9. Duty Cycle % : 100%
10. Opening/Closing time Sec: within less than 1sec.
11. Throughput 30-40 persons per minute.
COMBO TESTER Z134 + STAND Z134S (optional)
(with access control)
Wrist straps and ESD footwears are the first line of defense against
electrostatic charge build up on the human body. They are designed to carry
away this charge as soon as it is generated. At the same time the
wriststrap/footwear must remain electrically safe for the user. Thus, it is
important to test every wrist strap/footwear regularly.
The maximum wrist strap resistance should not be more than 10 meg ohms and
Footwear resistance should not be more than 35 Mega ohms. Also the
resistance should not be less than 0.75 Mohm as protection to the wearer
from dangerous voltages.
This COMBO TESTER is a combination Wriststrap & DUAL footwear tester which
checks these parameters under actual Realtime operating conditions. The
footwear section gives a warning if either of the Footwear is defective.
This is done by keeping 1 foot on the plate at a time.
Door Access System:
Before entering the EPA (ESD Protected Area) personnel need to test their
Wrist Strap/ESD footwear. Access into the EPA is allowed by the release of
the Electromagnetic lock only if the resistance of the Wrist Strap/ESD
footwear is within the Pass limits.
SPECIFICATIONS
Pass Range : Wrist strap 0.75 to 10.0 meg ohm
Footwear 0.75 to 35.0 meg ohm
Actuation : By gently pressing TEST button
Accuracy : + 10%
Power supplies : Included
EM Lock : Optional
Dimensions & Wt : (instrument) 125 x 75 x 29 mm 150 gms
(optional stand) 400 x 400 x 950 mm ht. 5 Kgs
Calibration : Recommended every 12 months.
Traceability : To national standards
Warranty : 12 months
For more details,
Visit - www.nabarcom.in ; [email protected] ; [email protected]
Contact : Mr. Vibhas Nabar - 9096388844 (Chairman & MD)