If you would like to support my channel please support my music.
https://markdb.bandcamp.com
PL1 - Pulse generator 1 sets the number of pulses (trigs) placed on the sequencer by this generator.
PL2 - Pulse generator 2 sets the number of pulses (trigs) placed on the sequencer by this generator.
LEN - Track length sets how many steps the track will have. This parameter is only available in PER
EUC - Euclidean mode switches the Euclidean sequencer mode on/off.
R01 - Rotation generator 1 rotates the trigs placed by generator 1 forward or backwards on the track.
R02 - Rotation generator 2 rotates the trigs placed by generator 2 forward or backwards on the track.
TRO - Track rotation rotates the trigs placed by both generator 1 and generator 2 forward or backwards
on the track.
Variant Modes
OP - Boolean operator lets you add or subtract the trigs generated from the two pulse generators in different ways based on mathematical logical expressions.
OR - all trigs from both generator 1 or 2 are placed the track.
XOR - trigs from both generator 1 or 2 are placed on the track unless they are added to the same sequencer step.
AND - only trigs added to the same sequencer step by generator 1 and 2 are placed on the track.
SUB - trigs from generator 1 are placed on the track unless generator 2 adds a trig on the same step as generator 1.
Please give a thumbs up and a subscribe
Thanks again for checking out my channel