How to troubleshoot Industrial Ethernet Switches with Diagnostic functions?

Опубликовано: 11 Октябрь 2024
на канале: Avcomm Technologies, Inc.
165
2

Industrial switches have industrial-grade protection to support work in harsh environments, but industrial switches may also encounter various failures.

The powerful fault diagnosis function of AVCOMM switches enables engineers to quickly discover and locate faults, reducing the complexity and time cost of troubleshooting, and improving the reliability and stability of industrial networks.

Next, let's take a look at how to view and use the switch's troubleshooting capabilities.
First, switch on the switch power supply, and connect the switch to the computer with a network cable.
Then open your computer's browser and enter your browser's ip address in the search box
Enter your username and password on the login screen, then click Log In
From the home screen, tap Diagnostics
On the Diagnostics screen
You can click LLDP to view device information. lldp is a link layer discovery protocol. You can view device details in the network topology, such as brand, ip address, and vlan.
You can click the mac table button to view the mac address of the port device, which helps the administrator troubleshoot and manage the network to ensure that the network runs properly.
Click the Port Statistics button to view and display performance indicators and statistics of each switch port.
It provides real-time or historical data about each port.
Click the port mirror button to configure a mirrored port. Use one port to monitor and analyze the sending and receiving information of different ports, so as to detect whether the port is faulty.
Click the Event Logs button to view switch logs. The logs record various events, errors, and status changes that occur on the switch, facilitating network administrators to troubleshoot, analyze performance, and audit security
Thanks for watching, if you want to learn more about this tutorial, please click follow.