Comparison before and after the status of high-frequency equipment.
The state of solid-state high frequency directly affects the
efficiency and power consumption of steel pipe welding.
This is a comparison before and after a high-frequency
state of 500 kilowatts. In the starting state, the DC voltage
is 450V, the DC current is 900A, and the welding speed of
M180*2.0mm steel pipe is 33 meters, the output power of
the high frequency is 405KW at this time. After adjustment,
the welding speed is increased to 44 meters, the high-frequency
DC voltage at this time is 440V, the DC current is 1100A, and the
output power at this time is 484KW. If the welding output
process is perfected, the high frequency welding efficiency
will be higher.