This is one of my learners practicing his live and dead tests as part of a training aid for his classmates. The video will be used to provoke class discussions on best practice. Please remember this learner is working towards his qualification and is not currently registered as a Part P domestic installer. The installation with be tested again by his QS and notified through the correct channels as required.
Remember if you calculate the circuits Zs on a minor work certificate you will not prove the circuit is connected to the supply authorities earth. This job was connected to a TT earthing arrangement so a loop test was also carried out between Line and Neutral.
EICR was recommended and carried out by the learners QS.