TIC Whited Out? Better Look Again!

Опубликовано: 20 Июнь 2026
на канале: Insight Training LLC
376
3

TIC Whited Out?

Better look again!

Many firefighters are unaware that certain models have a brief pause prior to switching from high to low sensitivity. The majority of fire service TICs split the overall temperature span into two ranges in order to balance out image clarity. In thermography, this is known as high and low gain. NFPA 1801 defines it as high and low sensivity. Low sensitivity is indicated by a green triangle within a green box that is visible in the upper left hand corner of TICs made since 2013.

Check out the view of the fire room through the lens of the FLIR K55 in our Train the Trainer from Virginia Department of Fire Programs.

#firefighter #thermalimaging #thermography #firefighting