T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display

Опубликовано: 13 Март 2026
на канале: VIN Invents
13,373
112

•| Tutorial/Test and Review |•
12v T2302 Timing Delay Relay Module Cycle Timer Digital LED Dual Display


•| Buy Link |•
12v T2302 Timing Delay Relay Module
https://s.lazada.com.ph/s.bNYGZ


•| Music |•
×ROFEU - Midnight Lover
   • ROFEU - Midnight Lover (Vlog No Copyright ...  
×Jarico - Island    • Video  
×Ehrling - You and Me
   • Ehrling - You And Me (Vlog No Copyright Mu...  


•| Specifications |•

Working voltage: DC 12V
Relay: 140v20a / 250v10a

Timing range:
0-999 seconds
0-999 minutes
0-999 hours

Working mode:
delay on, delay off, timing on, timing off, cycle on, cycle off

Size:
45.5mm*26.5mm*30mm 1.79*1.04*1.18"
Weight: 25g

Product Instructions:
Please pay attention for your first use.
You need wait 6s after your setting data, the module will save the date you have set after 6s.

Short press button SET: If you start the time setting mode, Nixie tube will blink. You could adjust the time T1 and T2 by button+ and button-. Please wait 5s after your setting date, the module will save the date you have set after 5s.

Long press button SET: if you start the parameter setting mode. There are two group parameter for your choice :
PO and P1. You could switch PO or P1 by short press SET. Under the parameter P0 and P1, you could set the timing
mode by the button+ and button-


PO - 0: Timing time mode : 0-999 sec.
PO - 1: Timing time mode : 0-999 min.
PO - 2: Timing time mode : 0-999 hrs.

P1 - 0: The relay will connect after you delay the T1 time.
P1 - 1: The relay will disconnect after you delay the T1 time.
P1 - 2: The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time, it finish.
P1 - 3: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time, it finish.
P1 - 4: The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time, it is cyclic.
P1 - 5: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time, it cyclic.

Example: A customer needs 10 seconds to start up and 20 seconds off.
Setup is as follows:
T1 set time 10, T2 set time 20
PO - 0 (T1 time range is seconds)
P1- 5 (timer work mode)



Thank you for watching
If you enjoy the video Please Like, Comment and Subscribe