How to Toshiba e-Studio reset error code C41 C43 C44 C45 181 182 212 242.

Опубликовано: 30 Октябрь 2024
на канале: Tech Humayun kabir
5,790
52

C41: Fuser thermistor or low temperature
C43: Fuser thermistor problem.
C44: Fuser problem after warm-up.
C45: Fuser thermistor problem.
To reset fuser errors: Go to service mode 08-400. To
Clear: Enter "0." Press "ENTER." Shut power oft and
turn back on again.
Error Code: C41
Thermistor or heater abnormality at power-ON: Abnormality of service call the thermistor is detected when power is turned ON or the temperature of the fuser roller does not rise in a specified period of time after power is turned ON.

1. Check the thermistors (1) Check if the connectors are disconnected. (2) Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly? (3) Check if the harnesses of the center, side and edge thermistors are open circuited. 2. Check the heater (1) Check if the heater is broken. (2) Check if the connector of the heater is disconnected. (3) Check if the thermostat is blown. 3. Check the MAIN board (1) Check if the connectors CN17 are disconnected. (2) Check if the conductor pattern on the MAIN board is short circuited or open circuited. (3) Replace the MAIN board. 4. Clear the status counter After repairing the matter which caused the error [C41], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Key in “400”, then press [START]. (3) Change the current status counter value “1” or “2” to “0”, then press [ENTER] or [INTERRUPT] (to cancel [C41]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state

All codes C01, C21, C26 l, C41, C43, C44, C45, C55, C94, C97, CA1, CA2, E01, E02, E03, E09, E12, E13, E14, E21, E40, E41, E44, E71, E72, E73, E86, E87, F14.