Inverter Ac Error Code E5 Systems E5 Error Code Service and Diagnostic

Опубликовано: 11 Июль 2026
на канале: @followers official
91
3

[Music] over voltage or too low voltage protection malfunction conditions an abnormal voltage rise or drop is detected by checking the specified voltage detection circuit the failure may be caused by abnormal power supply wiring mistake faulty Bridge rectifier and faulty IPM board troubleshooting is shown in figure

check whether the power voltage is normal restart the unit when the power supply is normal [Music] measure whether the outdoor terminal voltage is normal

if the value is not equal to power supply voltage check whether the wiring of power wires is correct

or whether the voltage between L and N is normal

foreign if the value is not equal to power supply voltage check whether the wiring of L and N is correct [Music] measure whether the input voltage of bridge rectifier is normal

if the value is not equal to the power supply voltage check whether the wiring of bridge rectifier is correct

if wiring is correct measure whether the voltage between p and N is normal

for normal value please refer to the table [Music] value is normal replace the IPM board

the IPM board and main board are in the same board replace the outdoor main PCB if the value is abnormal check whether the bridge rectifier is normal

measure whether positive and negative resistance values of the plus and negative pole between 2 3 are normally responding if positive and negative resistance values of one diode are both zero or infinite Bridge rectifier is abnormal [Music]

foreign

[Music]

foreign [Music]

foreign

[Music]

if Bridge rectifier is abnormal replace it

if Bridge rectifier is normal and there is PFC module replace the PFC module

if the error still exists check the wiring of reactor or inductance

everything

[Music]

if the wiring is correct measure the resistance value of reactor or inductance if the reactor or inductance is normal the value is zero

[Music] foreign

foreign

if the value is abnormal replace the reactor or inductance if the value is normal replace the IPM board if the IPM board and Main PCB are in the same board replace the outdoor main PCB [Music]