inverter Error Code P0 P4

Опубликовано: 11 Июль 2026
на канале: @followers official
372
2

If you like the video then like comment share and request to get our daily new video updates by subscribing the channel and stay with us thanks
To watch other videos of this channel:

ভিডিওটিভালোলাগলেলাইককমেন্টশেয়ারকরবেনএবংআমাদেরনিত্যনতুনভিডিওরআপডেটপেতেঅনুরোধকরবোচ্যানেলটিকেসাবস্ক্রাইবকরেআমাদেরসাথেইথাকুনধন্যবাদ
এইচ্যানেলেরঅনান্যভিডিওগুলোদেখতে:


********************************************************************
🚫 NOTE: All content used is copyrighted to Power
Use or commercial display or editing of the content without proper
authorization is not allowed
***************************************************************************
***************************************************************************
👉 PLEASE STAY CONNECT WITH US BY SUBSCRIBING OUR CHANNEL
AND DON'T FORGET TO CLICK THE BELL ICON 😊

if you like this video, please hit the Like Button.
If you found this video useful, please subscribe to Our Channel and click the bell icon to get notified of our latest videos.
If you love this video, please do share the video

Thank You!!
❤️❤️ Md Sirajul Islam ❤️❤️
****************************


singer bangladesh limited
#troubleshootingguide,
#fixingcommonissues,
#singerledtv,
#tvproblems,
#howtofixtvissues,
#tvrepair,
#ledtvtroubleshooting,
#singerledtvproblems,
#tvtroubleshooting,
#tvissues,
#troubleshootingtips,
#fixtvproblems,
#ledtvproblems,
#singerled,
#tvrepairguide,
#ledtvrepair,
#techsupport,
#singer,
#tvrepairtips,

inverter Error Code P0 P4,Code P0 P4,conditioner repair,commercial hvac,e4 error code,e6 error code,hvac,hvac apprentice,hvac basics,hvac career,hvac installation,hvac school,hvac tech,hvac technician,hvac tools,hvac trade,hvac training,hvac training videos,hvac troubleshooting,hvac videos,hvacr,hvacr videos,inverter ac pcb repair,voltas ac error code e4,window ac pcb repair,p4,p4 error code,air conditioner,p0 error,electric locha

1.    / @powerelectronicsworkshop  
2.    / @powerelectronicsworkshop  
3. https://studio.youtube.com/video/TTef...
4. https://studio.youtube.com/video/8KBT...
5.    • 🔥 Cozy Fireplace 4K (12 HOURS). Fireplace ...  
6.    • P1 Mini-Split Error Code – Perfect Aire  
7.    • inverter AC Error  Low Voltage Protection ...  
8.    • WYS Inverter Systems: P1 Error Code Servic...  
9.    • Top 20 youtube channel/MRbeast/T-series/pe...  
10.    • 🔥Views Kaise Badhaye Youtube Par | How To ...  
11.    • How Much YouTube Pays You For 1,000 Views ...   module fault or igbt over current protection

indoor unit displays P0 P4 which indicates IPM module fault or igbt over current protection malfunction decisions conditions P0 when the voltage or fault pin of IPM is not 5 volts the LED will show P0 and the air conditioner will be off

malfunction decision conditions P4 the LED will show P4 and the air conditioner will be off if there is an abnormal feedback signal including voltage currents rotating speed and so on from the inverter compressor failure could be caused by one wiring mistakes 2. IPM error three outdoor fan motor error 4. compressor error 5. outdoor main PCB error 6. system pressure error 7. bad ventilation of outdoor units

check the wiring between the main PCB and the compressor if the wiring is correct check if IPM is operating well

check the resistance value between p and uvw between n and uvw the normal vowel should be as Mega ohm order of magnitude and each two volts are equal [Music]

[Music] thank you

[Music]

or we can check the conductivity between P to uvw and N to uvw the positive conductivity uvw to p and ubw should be some value and the negative conductivity P to uvw uvw to n should be infinite [Music] foreign

[Music]

[Music]

PCB board please refer to the instructions for IPM check

if the result is abnormal replace the IPM board or replace the main PCB check the eev electrical expansion valve if the unit has one measure the resistance to check if there is any short circuits if yes replace the coil of eev measure the output voltage to the eev the value should be the same as the table if not replace the outdoor PCB check if ventilation of the outdoor unit goes well [Music] check if the outdoor fan operates well then find Solutions according to this solution for the malfunction of fan motors being out of control check the resistance value of the compressor terminal and check if the compressor is working well the normal resistance value of each two terminal are equal [Music]

thank you [Music]

if the resistance are not equal replace the compressor or hold outdoor units if the error still exists replace the outdoor main PCB